New independent testing of PH Insulation’s sandwich panels with polyisocyanurate foam confirmed that thermal insulation level of PIR stayed the same during 8 years of operation. The study was conducted at the testing center of St. Petersburg State University of Architecture and Civil Engineering. According to the tests, the R-Value of the polyisocyanurate in PH Insulation sandwich panel sample remained at 0.020 W/(m·K).

The measurement was made according to the Russian standard GOST R 70723-2023.

The testing was conducted in a climate chamber: the air temperature in the warm section was +19 °C, while in the cold section it reached -24 °C. The relative humidity in the chamber was maintained at 45 ± 5%. Two devices were used for measurements: the Metometer MES-200A and the multi-channel thermal conductivity meter IT-2-96. A unique feature of the testing setup at St. Petersburg State University of Architecture and Civil Engineering is its ability to test large material samples, which significantly enhances the accuracy of the tests.

The current test is yet another confirmation of the durability of PIR in PH Insulation sandwich panels. The previous testing where the R-Value after 8 years of operation was recorded at 0.021 W/(m·K), was carried out at the Construction Technologies and Materials Research Center LLC.

Панели для Яндекса.jpg

Sign up to our newsletter

All the most useful and interesting once a week

More news

For construction of the new building were used PH Insulation’s sandwich panels with PIR Premier, refrigeration doors, and PIR Plita® insulation boards.
09.06.2025
Minimum production times apply to products in standard colors and sizes
04.06.2025
A new type of sandwich panel will optimize the costs of constructing enclosing structures by combining the best qualities of the most popular insulation materials
29.05.2025
The automatic closer is compatible with all PH Insulation’s hinged doors, including half-hidden, threshold, and non-threshold models
29.04.2025

See our
projects

gototop